home *** CD-ROM | disk | FTP | other *** search
/ Professional Soft Collection 1.02 / Professional Soft Collection 1.02.iso / msdos622.rus / msdos_4.ddi / NET.TXT < prev    next >
Text File  |  1993-05-31  |  12KB  |  326 lines

  1. NET.TXT
  2. =======
  3. This file explains how to update network software files for the following
  4. networks:
  5.  
  6. 1. Microsoft LAN Manager Version 2.0 Enhanced and 100-Percent Compatible 
  7.    Networks
  8.  
  9. 2. Microsoft LAN Manager Version 2.0 Basic and 100-Percent Compatible 
  10.    Networks 
  11.  
  12. 3. Microsoft LAN Manager Version 1.x Enhanced and 100-Percent Compatible 
  13.    Networks
  14.  
  15. 4. Microsoft LAN Manager Version 1.x Basic and 100-Percent Compatible 
  16.    Networks
  17.  
  18. 5. Microsoft MS-Net and 100-Percent Compatible Networks
  19.  
  20. 6. 3Com 3+Share Version 1.6
  21.  
  22. Find the section below that corresponds to your network software.  
  23.  
  24. NOTE If you have a LAN Manager or 100-percent compatible network, and you
  25. are unsure of which version you are using, type NET CONFIG WORKSTATION 
  26. at the command prompt. If you see information about your configuration,
  27. you have an Enhanced version. This information indicates whether you
  28. have Enhanced version 2.0 or Enhanced version 1.x. 
  29.  
  30. If you receive an error message when you type the command, you have a 
  31. Basic version. To find out whether you have Basic version 2.0 or Basic 
  32. version 1.x, check the creation dates of the files in your LAN
  33. Manager directory (typically C:\LANMAN.DOS\BASIC). If the files
  34. are dated before July 1990, you have version 1.x. Files dated after
  35. July 1990 are typically version 2.0.
  36.  
  37. 1. Microsoft LAN Manager Version 2.0 Enhanced and 100-Percent Compatible 
  38.    Networks
  39. ========================================================================
  40.  
  41. To update LAN Manager version 2.0 Enhanced, replace your current 
  42. NETWKSTA.EXE and NETBEUI.DOS files with the new versions included
  43. with the MS-DOS 6.22 Supplemental disks. It's a good idea to preserve
  44. your current files by renaming them with a different extension,
  45. such as .OLD or .BAK.
  46.  
  47. To update LAN Manager version 2.0 Enhanced:
  48.  
  49. 1. Run the Setup program from the drive and directory that contains 
  50.    your Supplemental disk files and specify the drive and directory
  51.    to which you want to install your files.
  52.  
  53.    For example, if your Supplemental disk is in drive A, and you want
  54.    to install the files on drive C in your SUPP directory, type A: at the
  55.    command prompt, and then type the following:
  56.  
  57.    SETUP C:\SUPP
  58.  
  59. 2. When the Setup program starts, choose A if you want install the 
  60.    Supplemental disk files. Choose S if you want to install some
  61.    of the files--for example, just the network files.
  62.  
  63.    If you choose to install some of the files, Setup will prompt
  64.    you to install groups of files, including the MS-DOS 6.22 Network
  65.    drivers.
  66.  
  67. 3. After Setup finishes installing the Network files, rename these
  68.    original network files to back them up:
  69.  
  70.    NETWKSTA.EXE (usually in C:\LANMAN.DOS\NETPROG)
  71.    NETBEUI.DOS (usually in C:\LANMAN.DOS\DRIVERS\PROTOCOL\NETBEUI)
  72.  
  73. 4. Copy new version of NETBEUI.DOS to the same drive and directory as 
  74.    the old version of the file.
  75.  
  76. 5. Copy the new NETWKSTA.2XE file to the same drive and directory as 
  77.    the old NETWKSTA.EXE file. Rename the new file to NETWKSTA.EXE.
  78.  
  79. 6. Restart your computer. Or, if you have not installed MS-DOS 6.22,
  80.    run Setup now.
  81.  
  82. 2. Microsoft LAN Manager Version 2.0 Basic and 100-Percent Compatible 
  83.    Networks 
  84. =====================================================================   
  85.  
  86. To update LAN Manager version 2.0 Basic, replace your current
  87. REDIR.EXE, NET.EXE, and NETBEUI.DOS files with the new versions
  88. included with the MS-DOS 6.22 Supplemental disks. It's a good idea to 
  89. preserve your current files by renaming them with a different 
  90. extension, such as .OLD or .BAK.
  91.  
  92. To update LAN Manager version 2.0 Basic:
  93.  
  94. 1. Run the Setup program from the drive and directory that contains 
  95.    your Supplemental disk files and specify the drive and directory
  96.    to which you want to install your files.
  97.  
  98.    For example, if your Supplemental disk is in drive A, and you want
  99.    to install the files on drive C in your SUPP directory, type A: at the
  100.    command prompt, and then type the following:
  101.  
  102.    SETUP C:\SUPP
  103.  
  104. 2. When the Setup program starts, choose A if you want install the 
  105.    Supplemental disk files. Choose S if you want to install some
  106.    of the files--for example, just the network files.
  107.  
  108.    If you choose to install some of the files, Setup will prompt
  109.    you to install groups of files, including the MS-DOS 6.22 Network
  110.    drivers.
  111.  
  112. 3. After Setup finishes installing the Network files, rename these
  113.    original network files to back them up:
  114.  
  115.    REDIR.EXE (usually in C:\LANMAN.DOS\REDIR)
  116.    NET.EXE (usually in C:\LANMAN.DOS\BASIC)
  117.    NETBEUI.DOS (usually in C:\LANMAN.DOS\DRIVERS\PROTOCOL\NETBEUI)
  118.  
  119. 4. Copy new version of NETBEUI.DOS to the same drive and directory as 
  120.    the old version of the file.
  121.  
  122. 5. Copy the new REDIR.2XE file to the same drive and directory as 
  123.    the old REDIR.EXE file. Rename the new file to REDIR.EXE.
  124.  
  125. 6. Copy the new NET.1XE file to the same drive and directory as 
  126.    the old NET.EXE file. Rename the new file to NET.EXE.
  127.  
  128. 7. Restart your computer. Or, if you have not installed MS-DOS 6.22,
  129.    run Setup now.
  130.  
  131. 3. Microsoft LAN Manager Version 1.x Enhanced and 100-Percent Compatible 
  132.    Networks
  133. ========================================================================
  134.  
  135. To update LAN Manager version 1.x Enhanced, replace your current
  136. NETWKSTA.EXE file with the new version included with the MS-DOS 6.22
  137. Supplemental disks. It's a good idea ot preserve your current file
  138. by renaming it with a different extension, such as .OLD or .BAK.
  139.  
  140. To update LAN Manager version 1.x Enhanced:
  141.  
  142. 1. Run the Setup program from the drive and directory that contains 
  143.    your Supplemental disk files and specify the drive and directory
  144.    to which you want to install your files.
  145.  
  146.    For example, if your Supplemental disk is in drive A, and you want
  147.    to install the files on drive C in your SUPP directory, type A: at the
  148.    command prompt, and then type the following:
  149.  
  150.    SETUP C:\SUPP
  151.  
  152. 2. When the Setup program starts, choose A if you want install the 
  153.    Supplemental disk files. Choose S if you want to install some
  154.    of the files--for example, just the network files.
  155.  
  156.    If you choose to install some of the files, Setup will prompt
  157.    you to install groups of files, including the MS-DOS 6.22 Network
  158.    drivers.
  159.  
  160. 3. After Setup finishes installing the Network files, rename this
  161.    original network file to back it up:
  162.  
  163.    NETWKSTA.EXE (usually in C:\LANMAN.DOS\NETPROG)
  164.  
  165. 4. Copy the new NETWKSTA.1XE file to the same drive and directory as 
  166.    the old NETWKSTA.EXE file. Rename the new file to NETWKSTA.EXE.
  167.  
  168. 5. Restart your computer. Or, if you have not installed MS-DOS 6.22,
  169.    run Setup now.
  170.  
  171. 4. Microsoft LAN Manager Version 1.x Basic and 100-Percent Compatible 
  172.    Networks
  173. =====================================================================
  174.  
  175. To update LAN Manager version 1.x Basic, replace your current
  176. REDIR.EXE file with the new version included with the MS-DOS 6.22
  177. Supplemental disks. It's a good idea to preserve your current
  178. file by renaming it with a different extension, such as .OLD
  179. or .BAK.
  180.  
  181. To update LAN Manager version 1.x Basic:
  182.  
  183. 1. Run the Setup program from the drive and directory that contains 
  184.    your Supplemental disk files and specify the drive and directory
  185.    to which you want to install your files.
  186.  
  187.    For example, if your Supplemental disk is in drive A, and you want
  188.    to install the files on drive C in your SUPP directory, type A: at the
  189.    command prompt, and then type the following:
  190.  
  191.    SETUP C:\SUPP
  192.  
  193. 2. When the Setup program starts, choose A if you want install the 
  194.    Supplemental disk files. Choose S if you want to install some
  195.    of the files--for example, just the network files.
  196.  
  197.    If you choose to install some of the files, Setup will prompt
  198.    you to install groups of files, including the MS-DOS 6.22 Network
  199.    drivers.
  200.  
  201. 3. After Setup finishes installing the Network files, rename this
  202.    original network file to back it up:
  203.  
  204.    REDIR.EXE (usually in C:\LANMAN.DOS\BASIC)
  205.  
  206. 4. Copy the new REDIR.1XE file to the same drive and directory as 
  207.    the old REDIR.EXE file. Rename the new file to REDIR.EXE.
  208.  
  209. 5. Restart your computer. Or, if you have not installed MS-DOS 6.22,
  210.    run Setup now.
  211.  
  212. 5. Microsoft MS-Net and 100-Percent Compatible Networks
  213. =======================================================
  214.  
  215. To update MS-Net or 100-percent compatible networks, replace your
  216. current REDIR.EXE and SETNAME.EXE files with the new versions 
  217. included with the MS-DOS 6.22 Supplemental disks. It's a good idea to 
  218. preserve your current file by renaming it with a different extension, 
  219. such as .OLD or .BAK.
  220.  
  221. To update MS-NET or a 100-percent compatible network:
  222.  
  223. 1. Run the Setup program from the drive and directory that contains 
  224.    your Supplemental disk files and specify the drive and directory
  225.    to which you want to install your files.
  226.  
  227.    For example, if your Supplemental disk is in drive A, and you want
  228.    to install the files on drive C in your SUPP directory, type A: at the
  229.    command prompt, and then type the following:
  230.  
  231.    SETUP C:\SUPP
  232.  
  233. 2. When the Setup program starts, choose A if you want install the 
  234.    Supplemental disk files. Choose S if you want to install some
  235.    of the files--for example, just the network files.
  236.  
  237.    If you choose to install some of the files, Setup will prompt
  238.    you to install groups of files, including the MS-DOS 6.22 Network
  239.    drivers.
  240.  
  241. 3. After Setup finishes installing the Network files, rename these
  242.    original network files to back them up:
  243.  
  244.    REDIR.EXE (usually in the directory that contains your network files)
  245.    SETNAME.EXE (usually in the directory that contains your network files)
  246.  
  247. 4. Copy new version of SETNAME.EXE to the same drive and directory as 
  248.    the old version of the file.
  249.  
  250. 5. Copy the new REDIR.2XE file to the same drive and directory as 
  251.    the old REDIR.EXE file. Rename the new file to REDIR.EXE.
  252.  
  253. 6. Review your MSNET.INI file to make sure the REDIR command appears
  254.    before the SETNAME command when both appear in the same command
  255.    set.
  256.  
  257.    For example, suppose one of your command sets in MSNET.INI appears
  258.    as follows
  259.  
  260.    start rdr $1
  261.       chknet
  262.       loadniu -r -d -m:d -i:5 exniuw.xfm stdlc
  263.       xnsbios -m:d -i:5
  264.       session
  265.       setname $1
  266.       redir /1:26 /s:9
  267.       prtsc
  268.  
  269.    You would reverse the order of the SETNAME and REDIR commands so the
  270.    command set appears as follows:
  271.  
  272.    start rdr $1
  273.       chknet
  274.       loadniu -r -d -m:d -i:5 exniuw.xfm stdlc
  275.       xnsbios -m:d -i:5
  276.       session
  277.       redir /1:26 /s:9
  278.       setname $1  
  279.       prtsc
  280.  
  281. 7. Restart your computer. Or, if you have not installed MS-DOS 6.22,
  282.    run Setup now.
  283.  
  284. 6. 3Com 3+Share Version 1.6
  285. ===========================
  286.  
  287. To update 3Com 3+Share version 1.6, replace your current MSREDIR.EXE
  288. file with the new version included with the MS-DOS 6.22 Supplemental
  289. disks. It's a good idea to preserve your current file by renaming it 
  290. with a different extension, such as .OLD or .BAK.
  291.  
  292. If you have 3+Share version earlier than 1.6, contact your network
  293. vendor for an update.
  294.  
  295. To update 3Com 3+Share version 1.6:
  296.  
  297. 1. Run the Setup program from the drive and directory that contains 
  298.    your Supplemental disk files and specify the drive and directory
  299.    to which you want to install your files.
  300.  
  301.    For example, if your Supplemental disk is in drive A, and you want
  302.    to install the files on drive C in your SUPP directory, type A: at the
  303.    command prompt, and then type the following:
  304.  
  305.    SETUP C:\SUPP
  306.  
  307. 2. When the Setup program starts, choose A if you want install the 
  308.    Supplemental disk files. Choose S if you want to install some
  309.    of the files--for example, just the network files.
  310.  
  311.    If you choose to install some of the files, Setup will prompt
  312.    you to install groups of files, including the MS-DOS 6.22 Network
  313.    drivers.
  314.  
  315. 3. After Setup finishes installing the Network files, rename these
  316.    original network files to back them up:
  317.  
  318.    MSREDIR.EXE (usually in C:\3SHARE)
  319.  
  320. 4. Copy the new REDIR.2XE file to the same drive and directory as 
  321.    the old MSREDIR.EXE file. Rename the new file to MSREDIR.EXE.
  322.  
  323. 5. Restart your computer. Or, if you have not installed MS-DOS 6.22,
  324.    run Setup now.
  325.  
  326.